Rat Platelet Endothelial Cell Adhesion Molecule-1 (PECAM-1) Elisa Kit Instructions

This kit can only be used for scientific research, not for medical diagnosis.

Quantitative Detection Kit (ELISA) for Rat Platelet Endothelial Cell Adhesion Molecule-1 (PECAM-1)

user's Guide

[Rat platelet endothelial cell adhesion molecule-1 (PECAM-1) Elisa kit kit name]

Quantitative Detection Kit (ELISA) for Rat Platelet Endothelial Cell Adhesion Molecule-1 (PECAM-1)

[Use of rat platelet endothelial cell adhesion molecule-1 (PECAM-1) Elisa kit kit]

Quantitatively detect the content of platelet endothelial cell adhesion molecule-1 (PECAM-1) in rat serum, plasma, tissue fluid and other related fluid samples.

[Principle of rat platelet endothelial cell adhesion molecule-1 (PECAM-1) Elisa kit detection principle]

This kit uses double-antibody two-step sandwich enzyme-linked immunosorbent assay (ELISA). Add the standard and the test sample to the pre-coated rat platelet endothelial cell adhesion molecule-1 (PECAM-1) monoclonal antibody transparent enzyme label coated plate. After incubation for a sufficient time, wash to remove unbound components. , Add enzyme working solution, and after incubation for a sufficient time, wash to remove unbound components. Substrates A and B were added in sequence, and the substrate (TMB) was converted into a blue product catalyzed by horseradish peroxidase (HRP), which turned yellow under the action of acid. The concentration of cell adhesion molecule-1 (PECAM-1) was positively correlated. The OD value was measured at a wavelength of 450 nm. Based on the OD value of the standard and the sample, the content of rat platelet endothelial cell adhesion molecule-1 (PECAM-1) was calculated .

[Composition of rat platelet endothelial cell adhesion molecule-1 (PECAM-1) Elisa kit kit]

1

Enzyme coated plate

12 holes × 4 strips

7

Developer A liquid

3mL

2

Standard

0.3mL × 6 tubes

8

Developer B liquid

3mL

3

20 times concentrated washing liquid

15mL

9

Stop solution

3mL

4

Sample diluent

3mL

10

Instructions

1 serving

5

Special diluent

3mL

11

Sealing film

2 sheets

6

Enzyme reagent

3mL

12

sealed bag

1

Remarks: The concentration of standard products (No. 1 → No. 6) is: 16, 8, 4, 2, 1, 0.5μg / L

[Rat platelet endothelial cell adhesion molecule-1 (PECAM-1) Elisa kit required but not provided reagents and equipment]

1. 37 ℃ thermostat

2. Standard specification microplate reader

3. Precision pipettes and disposable tips

4. Distilled water

5. Disposable test tubes

6. Absorbent paper

[Procedures of rat platelet endothelial cell adhesion molecule-1 (PECAM-1) Elisa kit]

1. Preparation: Remove the reagent kit from the refrigerator and re-equilibrate at room temperature for 30 minutes.

2. Mixing solution: dilute the 20-fold concentrated washing solution with distilled water to the original one.

3. Add standard products and samples to be tested: take a sufficient number of enzyme-coated plates and fix them to the frame. Set up standard wells, sample wells to be tested and blank control wells, record the positions of each well in the standard wells. Add 50μL of standard product; first add 10μL of sample to be tested, and then add 40μL of sample diluent (that is, the sample is diluted 5 times); blank control well is not added.

4. Incubation: Incubate in a 37 ° C water bath or thermostat for 30 minutes.

5. Wash the plate: discard the liquid, pat dry on the absorbent paper, fill each hole with the washing solution, let stand for 1min, shake off the washing solution, pat dry on the absorbent paper, repeat the washing 4 times (you can also use the washing machine to press Instructions for washing the board).

6. Add enzyme-labeled working solution: add 50μL of enzyme-labeled working solution to each well, without adding blank control wells.

7. Incubation: Incubate in a 37 ° C water bath or thermostat for 30 minutes.

8. Wash the plate: discard the liquid, pat dry on the absorbent paper, fill each hole with washing liquid, let stand for 1min, shake off the washing liquid, pat dry on the absorbent paper, repeat the plate washing 4 times (you can also use the washing machine to press Instructions for washing the board).

9. Color development: add 50μL of developer A solution to each well, and then add 50μL of developer B solution, mix for 30s with a plate mixer (or gently shake for 30s by hand), and avoid color development at 37 ℃ for 15min .

10. Termination: Remove the enzyme labeling plate and add 50μL of stop solution to each well to stop the reaction (the color changes from blue to yellow).

11. Determination: Zero the blank holes, and within 15 minutes after termination, measure the absorbance (OD value) of each well with a wavelength of 450 nm.

12. Calculation: According to the concentration of the standard product and the corresponding OD value, calculate the linear regression equation of the standard curve, and then calculate the corresponding sample concentration on the regression equation according to the OD value of the sample. You can also use various application software to Calculation. The final concentration is the actual measured concentration times the dilution factor.

[Sample requirements for rat platelet endothelial cell adhesion molecule-1 (PECAM-1) Elisa kit]

1. The sample cannot contain sodium azide (NaN3) because sodium azide (NaN3) is an inhibitor of horseradish peroxidase (HRP).

2. The specimen should be extracted as soon as possible after collection. The extraction should be carried out according to relevant literature. The experiment should be carried out as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided.

3. The sample should be fully centrifuged, without hemolysis and particles.

[Notes for rat platelet endothelial cell adhesion molecule-1 (PECAM-1) Elisa kit]

1. The experiment is carried out in strict accordance with the instructions, and the result of the experiment must be determined by the reading of the microplate reader.

2. If the enzyme-labeled coated board is not used up after opening, it should be put into a sealed bag and added with desiccant immediately.

3. It is recommended that all standards, samples and blank controls be tested in duplicate, and the average value is taken to reduce the experimental error.

4. Keep in mind that the sample has been diluted 5 times. The calculation result is multiplied by 5 to obtain the actual concentration of the sample.

5. The quantitative range of this kit is 0.5-16μg / L, beyond this range, it is calculated from the extension of the standard curve. It is not used as an accurate quantitative result. Please dilute it with a special diluent to determine the accurate result (within 0.5-16μg / L ), Multiplied by the total dilution factor is the final concentration of the sample.

6. If the color is too light, the substrate incubation time can be extended properly.

7. In order to avoid cross-contamination, the tips, samples and blank controls should be replaced with a new one for each addition; the common components such as enzyme working solution, sample diluent and substrate should be cantilevered, and they should not touch the microwells. ; Do not reuse the sealing film.

8. The kits are used within the warranty period, and different batches of reagents should not be mixed.

9. Substrate B is sensitive to light and avoid prolonged exposure to light.

[Rat platelet endothelial cell adhesion molecule-1 (PECAM-1) Elisa kit operating procedures summary]

Prepare reagents, samples and standards

Add prepared samples and standards, and react at 37 ℃ for 30 minutes

Wash the plate 4 times, add the enzyme reagent, and react at 37 ℃ for 30 minutes

Wash the plate 4 times, add color developing solutions A and B, and develop at 37 ℃ for 15 minutes

Add stop solution

Read OD value within 15 minutes

Calculation

[Rat platelet endothelial cell adhesion molecule-1 (PECAM-1) Elisa kit detection range]

0.5μg / L-16μg / L

[Specification of rat platelet endothelial cell adhesion molecule-1 (PECAM-1) Elisa kit]

48 servings / box

【Storage of rat platelet endothelial cell adhesion molecule-1 (PECAM-1) Elisa kit】

Store at 2-8 ℃, protected from light and moisture.

【The rat platelet endothelial cell adhesion molecule-1 (PECAM-1) Elisa kit validity period】

6 months

IPC(Industrial PC)

Industrial Computer is simple,basic and stable functions could be needed. It could be used in 24 hours*365 with low power consumption, heat dissipation,and free from heat dissipation.
Industrial computer need to be dust-proof. Watertight do not mentioned.

Widely used in construction machinery, CNC equipment, medical equipment, video surveillance, factory automation.


14

Industrial Monitor

Industrial Computer,Industrial monitor,J1900 embedded computer,Industrial panel pc

Guangzhou Sosu Electronic Technology Co., Ltd. , https://www.sosuchina.com